Industrial Reverse Osmosis X1-Series Systems

Industrial Reverse Osmosis X1-Series SystemAXEON X1-Series 8” Industrial Reverse Osmosis Systems are designed as a cost-effective solution to the growing demand in industrial water treatment of tap water and well water for a multitude of applications in food & beverage, pharmaceutical, healthcare, microelectronics, power, chemicals, and agriculture.

With models ranging from 25 to 125 gallons per minute (30,000 to 180,000 gallons per day), the smart, clean utilitarian industrial design of the X1-Series allows for convenient installation, user-friendly operation, and ease of maintenance. These skid-mounted, package systems are pre-plumbed and pre-wired on a powder-coated steel frame complete with a preprogrammed computer, TDS probes, and panel-mounted pressure and flow instrumentation allowing for straight forward system monitoring and control.

Featuring robust components selected for enhanced performance, the X1-Series includes a stainless steel vertical multistage pump, stainless steel cartridge filter housing, stainless steel valving, and FRP pressure vessels with stainless steel side ports. The larger models also include VFD motor control of the pump and a motorized feed valve.

The X1-Series systems utilize energy-efficient ultra low energy membranes with 10% greater membrane surface area than standard 8” RO elements thus producing more pure water.

Benefits

  1. Over 25 Years of Manufacturing Experience
  2. Components Easily Accessible
  3. Conservatively Engineered for Reliable Long Term Performance
  4. Integrated Pre-Filtration
  5. Factory Tested to Ensure Trouble-Free Operation
  6. Easy Maintenance and Servicing
  7. Pre-Plumbed, Wired and Assembled
  8. Numerous Options and Upgrades to Suit Most Applications
  9. 1-Year Limited Warranty
  10. Made in the U.S.A.

Standard Features

  1. S-150 Pre-programmed Computer Controller*
  2. S-200 Pre-programmed Computer Controller w/VFD**
  3. Permeate and Concentrate Rotometers*
  4. Permeate and Concentrate Digital Paddle Wheels*
  5. Pre- and Post-Filter Pressure Gauges
  6. Pump Pressure and Concentrate Pressure Gauges
  7. Feed and Permeate TDS
  8. 8” Ultra Low Energy Elements with 440 SF Membrane
  9. 300 psig FRP vessels w/Stainless Steel Side Ports
  10. Multi-Cartridge Stainless Steel Filter Housing
  11. 5-Micron Sediment Cartridge Filters
  12. Vertical Stainless Steel Multistage Pump
  13. Composite Feed Solenoid Valve*
  14. Motorized Feed Valve**
  15. Stainless Steel Globe Throttling Valves
  16. Low and High Pressure Shut-Off Switches
  17. Powder-Coated Carbon Steel Frame
  18. Sch80 PVC Piping
  19. Permeate Sample Ports
  20. Chemical Feed Port
  21. Permeate Sample Ports
  22. Voltage: 220VAC 3PH 60 HZ

Optional Features

  1. S-200 Computer Controller***
  2. VFD***
  3. Programmable Logic Controller (PLC) w/Touch Screen
  4. Permeate and Concentrate Digital Paddle Wheels***
  5. Motorized Feed Valve***
  6. Concentrate Recycle Loop w/Flow Meter
  7. Permeate Divert
  8. Permeate Flush
  9. pH and/or ORP Sensor
  10. Chemical Feed System
  11. Chemical Feed Power Outlet
  12. Clean-in-Place (CIP) Ports
*Standard on Models X1-2280, X1-3280, X1-4280, X1-5280
**Standard on Models X1-3480, X1-4480, X1-5480, X1-6480
***Option available for Models X1-2280, X1-3280, X1-4280, X1-5280. Standard on larger models.

Specifications

Models X1-2280 X1-3280 X1-4280 X1-5280 X1-3480 X1-4480 X1-5480 X1-6480
Design  
System Capacity
(gpd / m3/hr)
38,800 / 131 43,200 / 196 57,600 / 262 75,000 / 327 90,000 / 393 120,000 / 524 150,000 / 655 180,000 / 818
Configuration Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass Single Pass
Feed Water Source (ppm) TDS < 2000 TDS < 2000 TDS < 2000 TDS < 2000 TDS < 2000 TDS < 2000 TDS < 2000 TDS < 2000
Standard Recovery Rate** 60% 70% 75% 70% 75% 75% 75% 75%
Recovery with Concentrate Recycle** 80% 80% 80% 80% 80% 80% 80% 80%
Rejection and Flow Rates  
Nominal Salt Rejection 99.3% 99.3% 99.3% 99.3% 99.3% 99.3% 99.3% 99.3%
Permeate Flow* (gpm / lpm) 20 / 75.6 30 / 113.4 40 / 151.2 50 / 189.0 60 / 226.8 80 / 302.4 100 / 378.0 125 / 472.5
Minimum Concentrate Flow (gpm / lpm) 14 / 53 14 / 53 14 / 53 14 / 53 14 / 53 14 / 53 14 / 53 14 / 53
Connections  
Feed (in) 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT3 FNPT3 FNPT3 FNPT
Permeate (in) 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT 2 FNPT 2 FNPT 3 FNPT 3 FNPT
Concentrate (in) 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/4 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT
Clean-in-Place Port (in) 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 1 1/2 FNPT 2 FNPT 2 FNPT
Chemical Feed Port (in) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
Membranes  
Membrane(s) Per Vessel 2 2 2 2 4 4 4 4
Membrane Quantity 4 6 8 10 12 16 20 24
Membrane Size 8040 8040 8040 8040 8040 8040 8040 8040
Vessels  
Vessel Array 1:1 1:1:1 1:1:1:1 2:1:1:1 2:1 2:1:1 3:1:1 3:2:1
Vessel Quantity 2 3 4 5 3 4 5 6
Pumps  
Pump Type Vertical Multistage Centrifugal Pump
Motor (hp / kw) 10 / 7.5 10 / 7.5 10 / 7.5 10 / 7.5 15 / 11 15 / 11 20 / 15 20 / 15
Electrical  
Standard Voltage 220V, 60Hz, 3PH, 19.5A 220V, 60Hz, 3PH, 19.5A 220V, 60Hz, 3PH, 19.5A 220V, 60Hz, 3PH, 37.5A 220V, 60Hz, 3PH, 37.5A 220V, 60Hz, 3PH, 37.5A 220V, 60Hz, 3PH, 46A 220V, 60Hz, 3PH, 46A
System Dimensions**  
L x W x H (in / cm) 112 x 35 x 85 /
284 x 89 x 216
112 x 35 x 85 /
284 x 89 x 216
112 x 35 x 85 /
284 x 89 x 216
112 x 35 x 85 /
284 x 89 x 216
194 x 41 x 85 /
493 x 104 x 216
194 x 41 x 85 /
493 x 104 x 216
194 x 41 x 85 /
493 x 104 x 216
194 x 41 x 85 /
493 x 104 x 216
Weight (lb / kg) 1850 / 839 2200 / 998 2350 / 1066 2500 / 1134 3900 / 1769 4150 / 1882 4400 / 1996 4600 / 2087

 

Operating Specifications

Design Temperature (°F / °C) 77 / 25.00 Maximum Free Chlorine (ppm) 0
Maximum Feed Temperature (°F / °C) 85 / 29.00 Design TDS (ppm) 2,000
Minimum Feed Temperature (°F / °C) 50 / 10.00 Maximum TDS (ppm) 3,000
Maximum Ambient Temperature (°F / °C) 120 / 48.89 Maximum Hardness (gpg) 0
Minimum Ambient Temperature (°F / °C) 40 / 4.44 Maximum pH (Continuous) 11
Maximum Pump Inlet Pressure (psi / bar) 85 / 5.90 Minimum pH (Continuous) 3
Minimum Pump Inlet Pressure (psi / bar) 45 / 3.10 Maximum pH (Cleaning 30 Min.) 12
Maximum Pump Pressure (psi / bar) 230 / 16.00 Minimum pH (Cleaning 30 Min.) 2
Maximum SDI Rating (SDI) <3 Maximum Turbidity (NTU) Up to 1

^Product flow and recovery rates are based on feedwater conditions of 2000 ppm TDS at 77°F. Treatment ability of the RO system is dependent on feed water quality. Higher TDS and/or lower temperatures will reduce product flow. An AXEON Applications Engineer can rate the units for these other feed water conditions.

^^Appropriate ltration must be installed in order to prevent premature membrane fouling.